BBTRZ 3+2-Core Flexible Copper Mineral-Insulated LSOH Fire-Resistant Power Supply Cable 0.6/1kV
-
Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.
-
Rated voltage0.6/1 kVInsulation materialMineral
-
Conductor materialCopper
-
Conductor MaterialCopperInsulation MaterialMineral
-
Rated Voltage0.6/1kVSizeNone
-
TypeMulti-Core Power Cable
The BBTRZ supply cable here is identified by a 3+2 arrangement and an LSOH sheath. Its conductors are copper and its insulation is mineral, in a flexible, fire-resistant construction rated 0.6/1kV. Keep the individual conductor allocation and complete material description with the power supply circuit specification.
Retain the actual LSOH sheath in the material comparison
The sheath description is separate from conductor material and insulation. Preserve all three requirements on the construction drawing when comparing power supply cables. This makes the intended build clear even where alternative products use a similar model designation.
What duties does the circuit assign to the 3+2 conductors?
Identify every required section and electrical function from the equipment connections. The notation does not assign neutral or protective-conductor roles or a reduced-core section ratio. Retain the allocation with the termination drawing so the selected cable has a definite electrical configuration.
Coordinate the flexible route with actual cable-end preparation
Obtain the bending and handling instructions applicable to the chosen build. Review access, connection space and the proposed route with compatible terminations. The cable-end arrangement should refer to the same material construction shown on the approved drawing.
Identify exact fire and sheath criteria where the project requires them
State any required method and acceptance conditions for fire, smoke or halogen performance. Review the selected build and supporting evidence for the intended installation. The LSOH label and ordinary fire-resistant function should not become unstated measured limits or test durations.
Keep conductor sections separate from the order length
Confirm individual requirements for the 50mm2, 3+2 selection against the supply circuit design. Give physical cable length independently and retain the approved allocation, LSOH build and end details in the order. Keep the exact project criteria with the final schedule.






Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.