Series illustrations. Actual configuration is subject to the confirmed drawing.
Black Street-Light LED Surge Protector SPD | Selected 10kV Uoc Current and IP67 Scope
-
Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.
-
Product Namethunder Arrester Surge Protection LED Power Protection Devices
-
Un100-277VAC,50(60)HzFunctionthunder Arrester Surge Protection
-
UC320VACIn5-10KA
-
Uoc10KVTa-40-85C
-
Warranty12 monthsColorBlack
-
MOQ500pcs
This black surge-protection device request serves street-light and LED-power equipment. Featured requirements include IP67 installed protection and separate nominal, continuous-operating and surge-rating scopes, with the actual selected electrical configuration to be resolved.
Resolve nominal and continuous voltage separately
Agree the requested 100–380 V range against Un 100–277 V AC at 50/60 Hz for the actual device. Clarify Uc 277 V versus 320 V AC as a distinct continuous-operating requirement.
Associate the agreed nominal and Uc definitions with the receiving lighting circuit. They should describe one selected SPD configuration rather than a combined range assembled from different voltage requirements.
Clarify current and surge-voltage definitions
Define the actual In 5–10 kA requirement and the roles of the featured 5 and 10 kA current figures. Retain Uoc 10 kV as its own open-circuit-voltage requirement, obtaining applicable selected-device support for the surge conditions.
Agree the actual protection mode, wiring scope and connected lighting load. The complete connection brief should distinguish operating conditions from surge-current and voltage-test requirements.
Specify installed environmental conditions
Define the actual assembly and mating conditions for the required IP67 scope. Obtain applicable support for installed protection and the required -40 to 85°C operating conditions.
Complete the street-light SPD specification with agreed nominal/Uc voltage, current definitions, Uoc, circuit mode and environmental requirements. These decisions keep the protection request associated with one actual device and receiving lighting arrangement.





Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.