IEC 60502-1 YJV YJV22 Copper XLPE/PVC Power Cable 0.6/1kV
-
Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.
-
Core countMultiple core optionsRated voltage0.6/1 kV
-
Conductor MaterialCopper or AluminumInsulation MaterialXLPE
-
Rated Voltage0.6/1.0KVSize1.5mm 2.5mm 4mm 6mm 10m 16mm 25mm 35mm
-
ApplicationBuilding, Construction, Industrial, Marine, Mining, Overhead, Power Distribution, Railway, Power Station, Underground, power distribution&transmission engineering, power transmission, power supply installation system, control system
-
JacketPVCRated CurrentNIL
-
TypeLow Voltage, YJV YJV22 YJV32Working Temperature90°C(162℉)
-
Product nameYJV22 IEC 60502-1 U-1000 R2V N2XY N2XH YJV Cu/XLPE/PVC Power CableSpecification2.5MM 4MM 6MM 10MM 16MM 25MM 35MM 50MM 95MM 120MM 150MM
-
ConductorPure CopperInsulation/JacketXLPE/PVC
-
Rated voltage0.6/1.0KVCore3 4 5 cores or Customized
-
FeatureUV Resistant abrasion and corrosion resistanceCertificateCCC CE RoHS ISO9001
The YJV/YJV22 copper power-cable family is rated 0.6/1kV with XLPE insulation and a PVC jacket for distribution, building and underground projects. Its construction has UV, abrasion and corrosion resistance. Complete the selected cable designation, conductor material and compatible core-size configuration before agreeing individual electrical duties and cable ends.
Define the four-core 50mm2 requirement
Confirm the 4C x 50mm2 family reference against the actual cable code and required conductor arrangement. Identify nominal section units for the chosen core-size description. Give every conductor an electrical function and equipment connection, retaining the individual allocation during the termination review rather than applying one generic configuration to every differently coded selection.
Retain the selected material drawing
Confirm the conductor required for the chosen designation while keeping XLPE insulation and PVC jacket separately identified. Use the complete selected construction to compare alternatives and review preparation for compatible cable ends. Obtain applicable installation information and consider the route, equipment access and available connection space with that actual build.
Review exact IEC and designation scope
Identify the IEC 60502-1 requirement and documents needed by the project. Check U-1000 R2V, N2XY and N2XH designation references against the selected construction. Retain the declared insulation and sheath with that review so the required technical build and documentation scope stay clearly identified.
Complete working and length quantities
Agree a consistent working-temperature declaration for the chosen cable and installation. Specify required cut length separately from conductor-size notation, using the 1M(3.28ft) option as the physical-length reference. Include the approved allocation, full construction drawing and agreed cable ends with the final quantities and required project documents.

Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.