Series illustrations. Actual configuration is subject to the confirmed drawing.

NG-A 2-Core Flexible Copper Mineral-Insulated Fireproof Industrial Emergency Power Cable 0.6/1kV

Share
  • Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.

Product description
Quotation & delivery
  • Rated voltage
    0.6/1 kV
    Insulation material
    Mineral
  • Conductor material
    Copper
  • Conductor Material
    Copper
    Insulation Material
    Mineral
  • Rated Voltage
    0.6/1kV
    Size
    None
  • Type
    Multi-Core Power Cable

The two-core NG-A cable is intended for industrial-project emergency power. It has copper conductors, mineral insulation and a flexible, fireproof construction, with a rated voltage of 0.6/1kV. Complete the emergency-circuit configuration through its individual conductor requirements, final sheath and equipment connections.

Define the two emergency connections

Give each conductor an electrical function, required section and connection reference from the industrial design. Retain those individual requirements beside the two-core arrangement in the cable schedule. Review the proposed terminations using that allocation so both equipment connections are described by a definite configuration.

Agree the complete flexible build

Keep copper conductor material and mineral insulation in the construction drawing while specifying the final sheath. Use the complete layer description to compare candidate cables and review preparation for the selected ends. Obtain handling and bending instructions applicable to the chosen flexible construction, considering access at the equipment and room for preparing both connections.

Use the emergency circuit's exact criterion

Identify any fire-test method, required survival period and acceptance conditions stated by the industrial emergency specification. Review supporting evidence for the selected cable build and relevant installation scope. Retain the ordinary fireproof construction characteristic alongside any precisely defined qualification required for that circuit.

Separate section from physical length

Confirm the individual conductor sections for the two-core 50mm2 selection. State cable cut length independently and include the final sheath, approved conductor allocation and agreed end preparation with the order quantities. Keep the circuit drawing, complete material reference and exact emergency-project criterion together so the final purchase describes the selected cable, its installation conditions and both equipment connections consistently.

Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.