US Inline Auto-Reset GFCI Power Cord, Black PVC Custom-Length Equipment Lead with Specified Termination
-
When You'll Get It:Nov 26 - Nov 30
-
Shipping & Support: In-stock items ship in 24 hours; custom orders ship per contract. Free shipping on orders over $10,000. For bulk buys, get a personal support rep and quick reimbursement if anything's defective.
-
AC Outlets Quantity1 OutletsCable Length1m, Customized
-
End Typec13Rated Current10 A, 13 A, 15 A
-
TypeAc Power Cord, GFCI Extension Cable
-
ApplicationComputer, Consumer Electronics, Industrial Equipment, Instrumentation, Telecommunication, Computer, Home Appliance,Female End TypeIEC
-
IP LevelIP11Male End TypeNema
-
MaterialCopper, PVCWire TypeSJTW
-
PlugNEMA 5-15PPlug Rating110V
-
Plug Current10AEnd ConnectorIEC C5, C7,C13,C14, C15, Right Angle C14, Right Angle C13
-
CableSVT,SJT, SJTW 18AWG/16AWGLength1M 1.5M or can be customized
-
ColorBlack, white, or othersJacketPVC
-
ConductorCopper,CCA, CCS
An inline GFCI lead should be specified around the receiving device and the actual cord assembly. This black US equipment power lead has an auto-reset function and PVC construction for the required connection arrangement.
Define the receiving termination
Confirm the equipment-end connector or termination needed by the receiving device. Include a drawing or specific mating detail before selecting the complete lead.
Keep that receiving form with the NEMA 5-15P supply connection. Both ends need to be defined together rather than inferred from a general equipment-power-cord description.
Set the wire build and reach
Specify the featured 14AWG three-wire requirement or agree an alternative SVT, SJT or SJTW construction. Confirm the conductor composition and exact cable build for the ordered version.
Length requests include 1m or 1.5m with custom reach available. Measure the actual route, including the positions of the supply plug, inline GFCI arrangement and receiving termination.
Match the complete electrical assembly
The supply plug has a 10A, 110V designation. Confirm the full cord current and voltage rating across the selected cable, GFCI unit and receiving connection before matching the equipment load.
The complete assembly should be defined as one power path. Provide the device requirement with the wire build, reach and both end forms in the inquiry.
Confirm the operating requirement
Obtain the operating instructions for the actual auto-reset GFCI assembly. Match the required operation to the equipment and installation that will use the lead.
A clear specification combines termination, route, wire construction, full rating and operation. These details give the inline GFCI cord a defined equipment requirement.