BBTRZ 4-Core Copper Mineral-Insulated LSOH Fire-Resistant Power Cable for Fire Protection 0.6/1kV
-
Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.
-
Rated voltage0.6/1 kVInsulation materialMineral
-
Conductor materialCopper
-
Conductor MaterialCopperInsulation MaterialMineral
-
Rated Voltage0.6/1kVSizeNone
-
TypeMulti-Core Power Cable
An LSOH sheath is a defining detail of this four-core BBTRZ fire-protection power cable. The conductors are copper and the insulation is mineral, with a rated voltage of 0.6/1kV. Fire-resistant construction is stated for the product; the circuit drawing completes the individual requirements of the four conductors.
Compare the LSOH build as three separate material requirements
Keep conductor material, insulation material and outer sheath description distinct in a cable comparison. Here those requirements are copper, mineral insulation and an LSOH sheath. Retaining all three helps the purchaser compare complete constructions, particularly when another power cable uses a similar family designation. Carry the same layer description into the approved drawing used for the termination and installation review.
Give the four cores definite connection duties
The electrical design should identify every conductor's function and required section. Four cores establish the arrangement but do not determine which duty belongs to a particular conductor. Show the equipment connections and proposed cable-end requirements beside the allocation. Include the intended route and the space needed at the connections so the cable schedule reflects the installation being planned.
What fire and sheath criteria does the project require?
Use the exact method and acceptance conditions whenever the specification calls for classified fire performance, smoke limits or halogen criteria. Review the selected construction and its supporting evidence against those requirements. The LSOH and fire-resistant descriptions remain useful product characteristics without being turned into an unstated test duration or measured limit.
Keep section selection and physical cable length independent
Confirm conductor sections for the four-core 50mm2 selection with the circuit drawing. State physical cut length separately, and retain the copper/mineral/LSOH construction in the order. Identify the terminations and end preparation for that build, with the required project criteria attached to the same schedule.






Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.