Series illustrations. Actual configuration is subject to the confirmed drawing.

RTTZ 4-Core Copper-Sheathed Mineral-Insulated Fire-Resistant Construction Electric Cable Rated 0.6/1kV

Share
  • Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.

Product description
Quotation & delivery
  • Rated voltage
    0.6/1 kV
    Insulation material
    Mineral
  • Conductor material
    Copper
  • Conductor Material
    Copper
    Insulation Material
    Mineral
  • Rated Voltage
    0.6/1kV
    Size
    None
  • Type
    Multi-Core Power Cable

The four-core RTTZ electric cable is intended for construction projects and has a copper-sheathed mineral-insulated build. Copper is the conductor material, and the rating is 0.6/1kV with stated fire resistance. Complete the construction configuration through the individual conductor requirements and the cable-end details used by the project design.

Four construction conductor duties

State the section, electrical function and equipment connection required for each conductor. Retain those individual requirements beside the four-core identity in the cable schedule. The approved allocation should identify the actual circuit configuration used to review terminations and end preparation.

Keep the copper sheath explicit

Describe conductor copper, mineral insulation and copper sheath separately on the construction drawing. Compare candidate cables against the full material build. Use the same layer description to review preparation and compatible terminations for the selected order.

Review route and fire acceptance

Obtain installation details applicable to the chosen construction and consider the intended route with equipment access and available connection space. If the project specifies a fire-test method, survival period or classified criterion, identify its exact acceptance conditions. Review selected-build evidence for the required installation, keeping ordinary fire resistance as a stated product function.

Retain independent physical quantities

Confirm individual conductor sections for the four-core selection and give physical cable cut length separately. Include the full material description, approved allocation and agreed end requirements with the final construction schedule. Retain the circuit drawing and exact project criterion as the references used to check the required configuration, performance scope and physical quantities of the cable being ordered.

Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.