BBTRZ Flexible Copper Mineral-Insulated LSOH Fire-Resistant Electric Cable for Construction Power 0.6/1kV
-
Quotation & delivery: Include your required quantity, destination and timing in the enquiry. Confirm the selected build, lead time, shipping charges and any return terms in the agreed quotation before ordering.
-
Rated voltage0.6/1 kVInsulation materialMineral
-
Conductor materialCopper
-
Conductor MaterialCopperInsulation MaterialMineral
-
Rated Voltage0.6/1kVSizeNone
-
TypeMulti-Core Power Cable
Mineral insulation and an LSOH sheath form the specified layers around the copper conductors of this BBTRZ construction cable. The build is flexible and fire resistant, rated 0.6/1kV. Agree the final conductor arrangement with the project drawing when completing the cable selection.
Start with the construction route and connections
Review the proposed route with available connection space and the termination arrangement. Confirm permitted bending and handling details for the selected flexible construction. Keep cable-end preparation with that review so the installation layout is coordinated with the actual cable build.
Which conductor layout does the project require?
Confirm the final core arrangement and the function and required section of each conductor. Retain the individual allocation with the equipment connections on the approved circuit drawing. This gives the cable schedule a clear electrical reference as the construction specification develops.
Retain the LSOH sheath requirement
Keep copper conductors, mineral insulation and the LSOH sheath as separate material requirements when comparing alternatives. If the project specifies exact fire, smoke or halogen test criteria, check those conditions for the selected build. A family designation should be accompanied by the construction and performance scope needed for the intended installation.
Make the physical order specific
The current technical option reads 50mm2. Confirm the required individual sections and physical cable length separately, then include the agreed core arrangement, material layers and cable-end details in the order description. Add any numbered IEC or exact fire requirement to the project schedule. Retain the approved cable drawing so the final construction, installation conditions and order quantities can be reviewed together.






Provide the product reference, selected configuration, quantity and destination. Confirm drawings, applicable ratings and acceptance requirements for the requested build. Lead time, shipping arrangements, charges and any return conditions should be reviewed in the agreed quotation before ordering.